model nokia 302
hi, phone not power on, just white display 1-2 sec, and power off.
* I read RPL..
Connect phone on selected interface...
Backup Certificates now...
Dead Mode is Selected
Waiting for USB device...
--- Insert cable and charger or press phone's power button! ---
Connection opened successfully
Waiting for communication response...
[BootRom] : 1st boot Ok!
ASIC ID: 000000030000022600010007400C192103032108
CPU ID : RAPU v21 , Features : Dead-Test , USBRPL , FullUSB
EM0 ID: 00001051
EM1 ID: 00001060
PUBLIC ID: DC710000FFFB3C40EBCCB6F9086C5864CB1065B6
ASIC MODE ID: 00
ROOT KEY HASH: 3AB5DB70B45D23F1ADEEBB5734160706
ROM ID: 2CAC45E23BC33C8B
Use RAPUv21_2nd.fg , Rev : 3.0 Ver : 12.14.0
Processing RAWLOADER...
FLIC : 00400020
Req : XSR 1.6
Use RAPUv21_XSR17_alg.fg , Rev : 3.0 Ver : 12.14.0
Processing PASUBTOC ...
Processing ALG ...
Boot Done! :)
TIME : Boot time : 00:00:02
Reopening the connection...
Waiting for response: 30
Waiting for response: 29
ADL: Check mode
Select ASIC [C900]
PAPUBkeys : 05BDE0ECC36CDEAA016A0565CB6BAE0B1585232E
ADL: Reading certificates...
Reading NPC certificate...
IMEI : 356335057801052
Reading CCC certificate...
Reading HWC certificate...
Reading R&D certificate...
Reading VARIANT certificate...
Reading PARTNERC certificate...
Reading MDM_KEYS certificate...
ADL: Reading certificates done! :)
ADL: Close_Session
Content: 000300000000000000000000000000
ADL: Reboot
Wait, reconneting...
NPC Certificate saved...
CCC Certificate saved...
HWC Certificate saved...
RPL saved : C:\InfinityBox\BEST\Backup\Cert\356335057801052_CR T_2nd.rpl
All done, Disconnecting
Elapsed: 00:00:20
Connect phone on selected interface...
* READ INFO
Phone found!
Series 40 Device detected!
read info... - Ok
Reading Phone Info....
Connected phone - Nokia 302
Software ver : V 14.78 31-08-12 RM-813 (c) Nokia
IMEI : 356335057801052
XappVer : 000006E0
DSP Ver : 104_PM5_14.78
PPM : V 14.78 31-08-12 RM-813 (c) Nokia L1
CNT : Content: movistar AR MVP 3.0 V 14.78 31-08-12 RM-813 (c) Nokia
Product SN : 0
Product code :
Long Prod.SN : 0
Hardware info=======
HWID :
Retu : 51
Tahvo : 00
Batery: 3870 mV
CMT BT: 4217-v924
LCDVer: TPO
Lock info ===========
IMEI : 356335057801052
IMEI spNet : 3A 65 33 05 75 08 01 05
IMEI svNet : 33 65 33 05 75 08 01 15 F1
Unable to read Lock table... :(
CRT308 Backup Created
SDD key status : Damaged!!!!!
CMLA Key status : Not Present
SimLock status : Damaged!!!!!
Security status : Ok
PA_SimLock Version :
PA_SL phone detected
User code : Crypted
MMC pwd : no any record found
UserDataExLevel : Full [PhoneBook, Calendar, PWD, SMS, Gallery]
Done!
What do u suggest??
hi, phone not power on, just white display 1-2 sec, and power off.
* I read RPL..
Connect phone on selected interface...
Backup Certificates now...
Dead Mode is Selected
Waiting for USB device...
--- Insert cable and charger or press phone's power button! ---
Connection opened successfully
Waiting for communication response...
[BootRom] : 1st boot Ok!
ASIC ID: 000000030000022600010007400C192103032108
CPU ID : RAPU v21 , Features : Dead-Test , USBRPL , FullUSB
EM0 ID: 00001051
EM1 ID: 00001060
PUBLIC ID: DC710000FFFB3C40EBCCB6F9086C5864CB1065B6
ASIC MODE ID: 00
ROOT KEY HASH: 3AB5DB70B45D23F1ADEEBB5734160706
ROM ID: 2CAC45E23BC33C8B
Use RAPUv21_2nd.fg , Rev : 3.0 Ver : 12.14.0
Processing RAWLOADER...
FLIC : 00400020
Req : XSR 1.6
Use RAPUv21_XSR17_alg.fg , Rev : 3.0 Ver : 12.14.0
Processing PASUBTOC ...
Processing ALG ...
Boot Done! :)
TIME : Boot time : 00:00:02
Reopening the connection...
Waiting for response: 30
Waiting for response: 29
ADL: Check mode
Select ASIC [C900]
PAPUBkeys : 05BDE0ECC36CDEAA016A0565CB6BAE0B1585232E
ADL: Reading certificates...
Reading NPC certificate...
IMEI : 356335057801052
Reading CCC certificate...
Reading HWC certificate...
Reading R&D certificate...
Reading VARIANT certificate...
Reading PARTNERC certificate...
Reading MDM_KEYS certificate...
ADL: Reading certificates done! :)
ADL: Close_Session
Content: 000300000000000000000000000000
ADL: Reboot
Wait, reconneting...
NPC Certificate saved...
CCC Certificate saved...
HWC Certificate saved...
RPL saved : C:\InfinityBox\BEST\Backup\Cert\356335057801052_CR T_2nd.rpl
All done, Disconnecting
Elapsed: 00:00:20
Connect phone on selected interface...
* READ INFO
Phone found!
Series 40 Device detected!
read info... - Ok
Reading Phone Info....
Connected phone - Nokia 302
Software ver : V 14.78 31-08-12 RM-813 (c) Nokia
IMEI : 356335057801052
XappVer : 000006E0
DSP Ver : 104_PM5_14.78
PPM : V 14.78 31-08-12 RM-813 (c) Nokia L1
CNT : Content: movistar AR MVP 3.0 V 14.78 31-08-12 RM-813 (c) Nokia
Product SN : 0
Product code :
Long Prod.SN : 0
Hardware info=======
HWID :
Retu : 51
Tahvo : 00
Batery: 3870 mV
CMT BT: 4217-v924
LCDVer: TPO
Lock info ===========
IMEI : 356335057801052
IMEI spNet : 3A 65 33 05 75 08 01 05
IMEI svNet : 33 65 33 05 75 08 01 15 F1
Unable to read Lock table... :(
CRT308 Backup Created
SDD key status : Damaged!!!!!
CMLA Key status : Not Present
SimLock status : Damaged!!!!!
Security status : Ok
PA_SimLock Version :
PA_SL phone detected
User code : Crypted
MMC pwd : no any record found
UserDataExLevel : Full [PhoneBook, Calendar, PWD, SMS, Gallery]
Done!
What do u suggest??