Welcome to Octoplus/Octopus Box Samsung software version 1.6.8
-----------------------------------------------------------------------------------
To connect SM-N900T phone you have to perform the following steps:
1. Disconnect USB cable from phone.
2. Go to Menu->Settings->More->About Device.
3.Tap on "Build number" 7 times to enable developer options.
4. Go to Menu->Settings->More->Developer options.
5. Turn on "USB Debugging" option.
6. Go to dial window.
7. Enter "*#0808#" number.
8. Select "DM+Modem+ADB".
9. Press Home button.
10. Go to dial window.
11. Enter "*#9090#" number.
12. Set "Diag config" to "USB" value.
13. Restart phone.
14. Press "Read Info" in software.
-----------------------------------------------------------------------------------
Platform: Samsung Android
Selected port: COM189
Selected model: SM-N900T
Reading info, please wait...
Please, press "OK" button on the phone to allow USB debugging..
Please, press "OK" button on the phone to allow USB debugging..
Detected phone model: SM-N900T
Firmware compiled date: Wed Feb 12 21:37:28 KST 2014
PDA version: N900TUVUCNB4
CSC version: N900TTMBCNB4
SW version: N900TUVUCNB4
Phone IMEI: Unknown
Phone SN: RV8F30H7EZN
Android version: 4.4.2 (KOT49H)
-----------------------------------------------------------------------------------
Platform: Samsung Android
Selected port: COM189
Selected model: SM-N900T
Mode: Normal
Phone model: SM-N900T
Firmware compiled date: Jan 29 2014
Firmware compiled time: 07:00:00
Firmware released date: Feb 12 2014
Firmware released time: 18:08:21
SW version: M8974A-AAAANAZM-2.0.10025
Old IMEI: 004400-15-202000-0
New IMEI: 357507-05-009287-6
Creating NVM backup
Reading NVM done!
Connecting to ADB, please waite...
Please, press "OK" button on the phone to allow USB debugging..
Please, press "OK" button on the phone to allow USB debugging..
Firmware compiled date: Wed Feb 12 21:37:28 KST 2014
PDA version: N900TUVUCNB4
CSC version: N900TTMBCNB4
SW version: N900TUVUCNB4
Phone IMEI: Unknown
Phone SN: RV8F30H7EZN
Android version: 4.4.2 (KOT49H)
Cheking Root
Erasing old IMEI. It can take some time. Please wait...
Reading security backup, please wait...
Backup saved as C:\Program Files\Octoplus\Octoplus_Samsung
\BACKUP\Security-SM-N900T-27-10-2014_17-36-57-.asec file
Phone will restart now. Please don't disconnect cable!
After phone being rebooted and powered on perform the following
steps:
1. Disconnect USB cable.
2. Wait for 1-2 minutes.
3. Connect phone via UART cable to the Box.
Serching phone...
when i try to use z3x as uart interface?
-----------------------------------------------------------------------------------
To connect SM-N900T phone you have to perform the following steps:
1. Disconnect USB cable from phone.
2. Go to Menu->Settings->More->About Device.
3.Tap on "Build number" 7 times to enable developer options.
4. Go to Menu->Settings->More->Developer options.
5. Turn on "USB Debugging" option.
6. Go to dial window.
7. Enter "*#0808#" number.
8. Select "DM+Modem+ADB".
9. Press Home button.
10. Go to dial window.
11. Enter "*#9090#" number.
12. Set "Diag config" to "USB" value.
13. Restart phone.
14. Press "Read Info" in software.
-----------------------------------------------------------------------------------
Platform: Samsung Android
Selected port: COM189
Selected model: SM-N900T
Reading info, please wait...
Please, press "OK" button on the phone to allow USB debugging..
Please, press "OK" button on the phone to allow USB debugging..
Detected phone model: SM-N900T
Firmware compiled date: Wed Feb 12 21:37:28 KST 2014
PDA version: N900TUVUCNB4
CSC version: N900TTMBCNB4
SW version: N900TUVUCNB4
Phone IMEI: Unknown
Phone SN: RV8F30H7EZN
Android version: 4.4.2 (KOT49H)
-----------------------------------------------------------------------------------
Platform: Samsung Android
Selected port: COM189
Selected model: SM-N900T
Mode: Normal
Phone model: SM-N900T
Firmware compiled date: Jan 29 2014
Firmware compiled time: 07:00:00
Firmware released date: Feb 12 2014
Firmware released time: 18:08:21
SW version: M8974A-AAAANAZM-2.0.10025
Old IMEI: 004400-15-202000-0
New IMEI: 357507-05-009287-6
Creating NVM backup
Reading NVM done!
Connecting to ADB, please waite...
Please, press "OK" button on the phone to allow USB debugging..
Please, press "OK" button on the phone to allow USB debugging..
Firmware compiled date: Wed Feb 12 21:37:28 KST 2014
PDA version: N900TUVUCNB4
CSC version: N900TTMBCNB4
SW version: N900TUVUCNB4
Phone IMEI: Unknown
Phone SN: RV8F30H7EZN
Android version: 4.4.2 (KOT49H)
Cheking Root
Erasing old IMEI. It can take some time. Please wait...
Reading security backup, please wait...
Backup saved as C:\Program Files\Octoplus\Octoplus_Samsung
\BACKUP\Security-SM-N900T-27-10-2014_17-36-57-.asec file
Phone will restart now. Please don't disconnect cable!
After phone being rebooted and powered on perform the following
steps:
1. Disconnect USB cable.
2. Wait for 1-2 minutes.
3. Connect phone via UART cable to the Box.
Serching phone...
when i try to use z3x as uart interface?
via Welcome to gsm-tips http://forum.gsmhosting.com/vbb/f684/n900t-imei-repoair-stuck-searching-1873294/
Aucun commentaire:
Enregistrer un commentaire